Order and logistics

 

  Updated: 10 May 2020

 

View Ewert Johansson's LinkedIn profile

Sitemap              Subscribe to News

 

Startpage > Products > Air Quality > Ionization > ACU Print

printer-friendly page

 

 

ACU Print

 

The ACU Print is a multifunction device, designed specifically as an air purifier for:

  • dental laboratories

  • hair and beauty salons

  • pharmacies

  • copying spaces

  • photo labs

  • orthopedic workshops

  • printing works

  • sign makers and for many other professions where it is necessary to reduce the risk of inhalation of different chemical substances.

The ACU Print can be mounted under the ceiling or on the wall horizontally or vertically. It can also be mounted on a table.


ACU Print

 

CE-decl.

Reduction
of

Press

Air
purif. rod

 

 

 

air
contamin.

Release

Info sheet

 

 

 

Particles are solid objects ranging from millimeters in size to one millionth of a millimeter.

The size determines whether they are floating in the air or if they fall to the floor.

A large amount of particles enters buildings from the air outside. How many particles that enter depends on the building ventilation system, if there are leaks and how the building is ventilated.

Particles can also occur indoors. Tobacco smoke, gas flames in stoves, burning candles, cooking, textiles, cleaning etc. give rise to particles.

Some of the indoor particles are skin particles from people living on the premises.

How you are affected by particles depends on the amount, size and occurrence of harmful substances in or on the particle surface. Indoor air should have as low levels of particles as possible.

   

 

The ACU Print purifier proves that air treated with air purification technology improves the condition of people suffering from

  • asthma

  • hay fever

  • allergies

  • depressionsr

  • fatigue

  • headache

Particles purified with the ACU Print exist in different sizes according to below:

  • nanoparticles, approx. 0.0001-0.05 μm, which for instance corresponds to larger gas molecules, very small viruses or metal dust

  • ultrafine particles, about 0.05-0.1 μm, which include oil mist, large viruses, large metallic dust, tobacco smoke

  • submicronic particles about 0.1-1 μm, such as bacteria and tobacco smoke

  • grova partiklar, större än 1 µm, som t.ex. omfattar hushållsdamm, pollen och synlig smuts

  • coarse particles, larger than 1 μm, such as household dust, pollen and visible dirt

Particles which are 40 μm or larger are visible to the eye.

 

 

 

   

Press-

CE-

 
     

 

  release declaration  

 

 
 

Copying spaces, maximal room area/room volume in m2/m3

Model

ACU Print

Area

42m2 / 100m3

Noise level

30 dB(A)

Effect/Consumption

24W

Dimension

545 x 210 x 145 mm
 
 
 
 

ACU Print is highly efficient against the very smallest particles and the purifying effect is very significant and quick for particles less than 0.3um.

Researchers have found that this purification technique efficiently removes small particles. (Lehtimäki)

 
 

Other distinctive features of the ACU Print

  • reduces 70% of pollutants within the first 10 minutes

  • very sinificant reduction of bacteria

  • max 44dB sound level

  • significant reduction of odors and contaminants

  • provides optimal quality of indoor air

  • increases the level of concentration and productivity among smokers

  • prevents airborne diseases (colds, fluids, etc.)

  • ensures good hygiene

 
 

Air Quality Levels

PM2.5 24h
Average concentration

Effects on Health

Level

Air Type

μg/m3

invisible

I

Very good

0 - 35

Good air quality, almost no air pollution

II

Good

36 - 75

Acceptable air quality, but some pollutants may have a small effect on health on a handful of sensitive persons.

III

Light
pollution

76 - 115

Vulnerable people will experience some degree of discomfort.

IV

Medium pollution

116 - 150

Vulnerable people will suffer a high degree of discomfort. It may also affect otherwise healthy people's hearts, lungs and respiratory systems.

V

Heavy pollution

151 - 250

Vulnerable people will suffer even further from discomfort.

Many people will suffer severe symptoms.

VI

Serious pollution

> 251

Healthy people will suffer severe symptoms.

 
 

Air Quality Levels

PM10 24h
Average concentration

Effects on Health

Level

Air Type

μg/m3

invisible

I

Very good

0 - 50

Good air quality, almost no air pollution

II

Good

51 - 150

Acceptable air quality, but some pollutants may have a small effect on health on a handful of sensitive persons.

III

Light
pollution

151 - 250

Vulnerable people will experience some degree of discomfort.

IV

Medium pollution

251 - 350

Vulnerable people will suffer a high degree of discomfort. It may also affect otherwise healthy people's hearts, lungs and respiratory systems.

V

Heavy pollution

351 - 4200

Vulnerable people will suffer even further from discomfort.

Many people will suffer severe symptoms.

VI

Serious pollution

> 421

Healthy people will suffer severe symptoms.

 

More on particle monitors >

 
 

E-post: lars@fjellcom.se

Tel: +46(0)31-287202

Mobil: +46(0)706-755561

Disclaimer

Webmaster

blog counter